How to use

How to use Tube Type (63ml)

Confiad | 2013.11.03 20:58 | Inquiry 7582
1. Directions

  1) Open Component-B Tube. Trim tip 1/4"(6mm) all non threaded part.
    

  2) Inject Component-A into Component-B Tube. Hold Component-B tube upright to avoid spills.
      Slowly squeeze out around 2/3 air in Component-B tube.
      Inject Component-A into Component-B tube by squeezing.
     

  3) Close Component-B tube before mixing.
      Close applicator cap tightly onto Component-B tube after squeeze out

      around 2/3 air in Component-B tube.
     

  4) Hold Component-B tube upright. 
      Mix "thoroughly" and "homogeneously" adhesive for around 5 minutes.
     

  5) Trim Applicator cap starting just below the tip.
     

  6) Discharge small amount from tube. Immediately fill joint 1/3 to 1/2 full.

     


※ For more information, see ConfiAd® Fabrication and Installation manual.

    Click !!


2. Cautions 
   Contains methylmethacrylate resin and benzoylperoxide(less than 10%)
   Cartridges should be stored in a dark and dry place.

   Keep away from heat, sparks, open flame and other combustible materials.
   Avoid contact with eyes, skin and clothing. 
  
   Avoid breathing vapor and use only with adequate ventilation.
   Wash hands thoroughly after handling.
   
   Keep away from Children.

3. First Aid 
   In case of contact with eyes, immediately flush eyes with plenty of water for at least 15 minutes,
   call a physician. For skin, wash with soap and water.



twitter facebook me2day Yozm
5(1/1Page)
Technical Data
Number Title Writer Inquiry Date
5 [Adhesives] ConfiAd Bulk Type Confiad 7459 2013.11.03 21:05
4 [Adhesives] How to use Cartridge Type (50ml / 75ml / 250ml / 490ml) Confiad 7504 2013.11.03 21:00
>> [Adhesives] How to use Tube Type (63ml) Image Attached file Confiad 7583 2013.11.03 20:58
2 [Adhesives] Storage and Handling Confiad 7323 2013.11.03 20:56
1 [Adhesives] Safety Information Confiad 7431 2013.11.01 18:44